Date:05-14-2024STATE OF CALIFORNIA 
LAST AND NEXT SAMPLE REPORT
SYSTEM NO.:4200854SYSTEM NAME:IMERYS FILTRATION MINERALS, INCCOUNTY:SANTA BARBARA 
SOURCE NO.:012SOURCE NAME:WELL 12SOURCE CLASS:NCNCSTATUS:A



Click to hide / show columns: PS Codes | Group Name | Analyte Number | Analyte Name | Detected Level |Less Than | RL | Unit | MCL | DLR | Last Sampled | Frequency | Next Due | Notes

PS Codes Group Name Analyte Number Analyte Name Results Unit MCL DLR Last Sampled Frequency Next Due Notes
Detected Level Less Than RL
CA4200854_012_012 SECONDARY/GP-202508 1928 ALKALINITY, BICARBONATE 310.000 20.000 MG/L 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1919 CALCIUM 96.000 0.100 MG/L 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1929 ALKALINITY, CARBONATE < 20.000 MG/L 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1017 CHLORIDE 72.000 4.000 MG/L 500 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1905 COLOR < 3.000 UNITS 15 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1022 COPPER, FREE < 10.000 UG/L 1000 50 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 2905 FOAMING AGENTS (SURFACTANTS) < 0.050 MG/L .5 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1915 HARDNESS, TOTAL (AS CACO3) 440.000 0.210 MG/L 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1021 HYDROXIDE AS CALCIUM CARBONATE < 20.000 MG/L 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1028 IRON < 50.000 UG/L 300 100 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1031 MAGNESIUM 48.000 0.050 MG/L 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1032 MANGANESE < 10.000 UG/L 50 20 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1920 ODOR < 1.000 TON 3 1 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1925 PH 7.520 0.100 pH 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202601 1050 SILVER < 1.000 UG/L 100 10 01-19-2023 36 2026/01
CA4200854_012_012 SECONDARY/GP-202508 1052 SODIUM 34.000 0.500 MG/L 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1064 CONDUCTIVITY @ 25 C UMHOS/CM 980.000 2.000 UMHO/CM 1600 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1055 SULFATE 100.000 4.000 MG/L 500 .5 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1930 TDS 620.000 10.000 MG/L 1000 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 0100 TURBIDITY 0.400 0.100 NTU 5 .1 08-17-2022 36 2025/08
CA4200854_012_012 SECONDARY/GP-202508 1095 ZINC < 10.000 UG/L 5000 50 08-17-2022 36 2025/08
CA4200854_012_012 INORGANIC-202601 1002 ALUMINUM < 50.000 UG/L 1000 50 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1074 ANTIMONY, TOTAL < 2.000 UG/L 6 6 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1005 ARSENIC 3.700 2.000 UG/L 10 2 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1010 BARIUM 77.000 10.000 UG/L 1000 100 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1075 BERYLLIUM, TOTAL < 1.000 UG/L 4 1 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1015 CADMIUM 1.100 1.000 UG/L 5 1 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1020 CHROMIUM < 10.000 UG/L 50 10 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202508 1025 FLUORIDE 0.390 0.100 MG/L 2 .1 08-17-2022 36 2025/08
CA4200854_012_012 INORGANIC-202601 1030 LEAD < 1.000 UG/L 5 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1035 MERCURY < 0.200 UG/L 2 1 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1036 NICKEL 12.000 10.000 UG/L 100 10 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1045 SELENIUM 19.000 2.000 UG/L 50 5 01-19-2023 36 2026/01
CA4200854_012_012 INORGANIC-202601 1085 THALLIUM, TOTAL < 1.000 UG/L 2 1 01-19-2023 36 2026/01
CA4200854_012_012 NITRATE/NITRITE-202411 1040 NITRATE < 0.400 MG/L 10 .4 11-29-2023 12 2024/11
CA4200854_012_012 NITRATE/NITRITE-202611 1041 NITRITE < 0.400 MG/L 1 .4 11-29-2023 36 2026/11
CA4200854_012_012 REGULATED SOC-202508 2414 1,2,3-TRICHLOROPROPANE < 0.001 UG/L 0.005 08-17-2022 36 2025/08
PS Codes Group Name Analyte Number Analyte Name Detected Level Less Than RL Unit MCL DLR Last Sampled Frequency Next Due Notes

RL – Reporting Level means the level to which the laboratory reported the presence of an analyte. For radionuclides, Reporting Level is the MDA95.

DLR – Detection Limit for purposes of Reporting (DLR) means the designated minimum level at or above which any analytical finding of a contaminant in drinking water resulting from monitoring required under Chapter 15 of Title 22 shall be reported to the State Board (California Code of Regulations Section § 64400.34)

For addtional definitions, please refer to our data dictionary.